Heating System

Heating System


Malfunction (symptoms) Probable Causes Corrective Action (remedies)
"Furnace ""whines"" when operating" Spoiler screw in air inlet orifice protruding too far into inlet Turn spoiler adjustment screw to back out of orifice inlet. Check intake / exhaust vent for damage or obstructions
Pilot light will not stay lit Faulty sight glass or burner door gaskets letting in draft Repair or replace gaskets
Defective exhaust/intake vent letting exhaust gas flow back to pilot light area Remove vent collar and sleeve and inspect for damaged exhaust support brackets; repair or replace.
Furnace pilot light will not light using ignition coil LPG tank empty Refill tank
Air in LPG lines Purge air from lines
"Furnace pilot light will not light from ignition coil but lights using a stick match" Low battery voltage Recharge domestic batteries
"Furnace pilot light is lit but main burner will not light" Domestic batteries too low to operate furnace blower (Which sets air-actuated switch) Recharge domestic batteries
Air trapped in LPG lines from last fillup Purge air from lines
All pilot lights are burning a blue flame (no orange tip) Excessive air in LPG lines Purge lines of air.
Pilot light of only one appliance is burning an all blue flame (no orange tip) "Air to gas ratio at pilot light out of adjustment" Check and adjust as required
Main burner remains lit when pilot light is turned off Inoperative safety valve Repair or replace.
Oven or range burners will not light Empty LPG tank Refill LPG tank
Pilot light out Relight pilot light
"One range burner will not light but all other burners operate stisfactorily" Dirty Burner Remove and clean.
Oven/range pilot light will not stay lit (garlic like odor present) Dirty Pilot light tube Clean pilot light burner
Pilot light improperly adjusted Correct adjustment
Strong draft over range top Close windows in immediate area (use only overhead ventilating fans and oven/range power vent for ventilation)
Empty LPG tank Refill LPG tank
Oven main burner will remain lit when pilot light is extinguished Inoperative safety valve Only a qualified gas equipment service representative should attempt repair on the safety valve component(s)