LPGSystem

LPGSystem


Malfunction (Symptoms) Probable Causes Corrective Action (remedies)
Pilot light will not stay on Air or moisture in lines and / or tank "Bleed system or if necessary fill LPG Tank. If problem continues or excess moisture is evidenced clean tank."
Pilot light valve out of adjustment Adjust
Constricted lines "Relieve constriction or replace line (s)"
Gas flame not blue and/or not producing enough heat Not enough air in burner mixture Adjust ratio of air to gas.
Clogged furnace or water heater air vent Clean vent
Impurities in LPG System Clean and refill system.
No gas flow at burner or burner will not stay on "Defective valve or constricted line and/or burner holes." "Remove constrictions; replace defective valve burner or LPG line."
Pilot light valve out of adjustment Adjust
"Air in coach ""stuffy""" "Clogged exhaust vent(s) on range water heater and / or furnace" "Open windows doors and range vent to remove exhaust fumes; then remove constrictions from vents."
"A ""garlic"" odor indicates LPG leakage or an open unlighted burner on the range" "Close service valve immediately. Open all windows range vent and doors. Do not light any matches or operate any gasoline or electrical equipment nearby until the leak is found and corrected or until the interior of the coach is free of all gas vapors. Leak check system."
Constricted or missing pilot light tube Remove constriction from tube or repair pilot light tube.